Special Contactor for Capacitor Matching MC series Summary MC contactor is specially designed for switching capacitors. It is equipped with advanced closed contacts. First, the auxiliary contacts guide current through the series of advanced closed contacts to ensure that the input current is within acceptable range. This stage takes 2-10 Ms. Then the main contact closure contacts connect the capacitor to the circuit completely, and the auxiliary contacts are automatically disconnected (the over-current intensity of 2.5 and 5 kV Ar models is ensured by special strengthening contact material).
●Auxiliary contact block ●Three-phase connection ●Possible capacitor connection up to 60 kvar, ●Coil voltage: 220-230VAC 50/60 Hz ●Compliance with IEC-497 Standard ●Long electrical life ●UL certification (12, 16, 20 and 25 kvar models) |
Advantage ●Long service life of contactor ●Reduction of Reactive Power Faults Caused by Contactor Faults (Compensation Faults) ●Reduction of capacitor failures ●Avoiding Voltage Fluctuation and Improving Power Quality ●Reduced maintenance intervals for unexpected failures and compensation systems. ●Reduction of loss in facility production. | MC series
|
Product model |
Maximum Operating Power(kvar) |
Rated current(A) |
Capacitor Unit Model |
|
220~240V |
400~450V |
500~550V |
|
MC-9b |
5kvar
13A |
9.7kvar
14A |
14kvar
16A |
21.6A |
AC-9 |
|
MC-12b |
6.7kvar
18A |
12.5kvar
18A |
18kvar
21A |
28.4A |
AC-9 |
|
MC-18b |
8.5kvar
22A |
16.7kvar
24A |
24kvar
30A |
37.8A |
AC-9 |
|
MC-25b |
10kvar
26A |
18kvar
26A |
26kvar
30A |
40.5A |
AC-9 |
|
MC-32a |
15kvar
39A |
25kvar
36A |
36kvar
42A |
56.1A |
AC-9 |
|
MC-40a |
20kvar
52A |
33.3kvar
48A |
48kvar
55A |
74.8A |
AC-9 |
|
MC-50a |
20kvar
52A |
40kvar
58A |
58kvar
67A |
90.4A |
AC-50 |
|
MC-65a |
25kvar
66A |
45.7kvar
66A |
66kvar
76A |
102.9A |
AC-50 |
|
MC-75a |
29.7kvar
78A |
54kvar
78A |
78kvar
90A |
121.6A |
AC-50 |
|
MC-85a |
35kvar
92A |
60kvar
87A |
92kvar
106A |
143.4A |
AC-50 |
|
MC-100a |
37kvar
97A |
62kvar
89A |
94kvar
109A |
146.5A |
AC-50 |
|
Note: When the switch is switched on, it must be discharged first (the maximum residual voltage of the terminal is less than or equal to 50V) to prevent short circuit. The current of the gG fuse must be 1.5~2 times of the rated current. |
 |
Thyristor switch SC-225 / SC-325 / SC-250 / SC-350
Summary SC series dynamic switching contactors are used in systems with rapidly changing loads. After using SC series dynamic contactors, the switching time of capacitors used to provide capacitive power to the system is less than 20 ms (1 cycle), which can bring more effective compensation for switching load quickly, such as flat head welder, crane and arc furnace. |
|
●Response time is less than 20 ms ●Reactor heat input ●Thermal protection ●Warning LED ●Long service life ●Easy installation ●Work quietly ●Flip-flop with RS-485 and DC voltage ●Flip-off characteristic of capacitor when voltage is higher than Vmax. Radiator design allows continuous operation at higher loads and higher temperatures ●FFT ensures high reliability in high harmonic environment |
Technical characteristics ●Working voltage 480/690V ●Maximum power 25/50 KVAr ●Frequency 45/60 Hz ●Triggering 5-30VDC ●Working temperature - 10 C, +55 C. ●Storage temperature - 10 C, +75 C. ●Humidity 95% ●Shell Protection Level IP-00 ●Standard EN 60947-1 ●Dimensions: 275.7 mm x 140 mm X 212.1 mm |
|
25 KVA |
50 KVA |
|
Two Tristors make up a triangle(400V) |
SC-225 |
SC-250 |
|
Three Tristors form a star(690V) |
SC-325 |
SC-350 |
|
It is suggested that these products be used in ENT. SPD series overload protection devices. |
|